Alech01  sistema chiamata infermiera wireless

"Alech01" is the new professional wireless calling system produced by Alech srl in collaboration with CS Elettronica. The Alech01 system consists of a series of call buttons which, when activated, are connected to the signal to one or more receivers of different fixed or portable types (wrist display, wall display, management software, etc.). Dedicated receivers show alphanumeric information, e.g. room number, department name or only room number etc. Installation is immediate and without the need for additional electrical connections or building works. The push-button panels operate on battery power with a capacity of approximately 30,000 cycles. So we could stimulate a duration of about 5 years. Starting from a basic system, you can then expand it to your liking, in fact they are available in addition to the push-button panels call-only standard, other versions with differentiated call functions to different operators, etc. available call buttons for bathroom with cord, outside door lights, management software and check received calls etc. With the "On Air" implementation you then have the option to record the selected calls on: Tablets, Smatphones, Smartwatches, portable PCs, fixed PCs, use your own Wi-Fi network or directly from the WEB. 4 good reasons to choose the Alech01 call system

 • Immediate installation of the system

 • Modularity and free implementations later

 • No masonry work planned

 • Operating distance of about 400 meters in free field but expandable with appropriate signal repeaters.

• Easy and immediate system installation

• Easy implementation even later

• Masonry works are not necessary

• Long operating distance

• The existing wi-fi network can be used

• The situation can be checked in real time

• Long battery life

BLS call keypads

All “BLS” series keyboards can be with one or three channels, with or without a pin; they are equipped with a lithium battery that allows the use of about 30,000 calls. The three-channel keypads can make three different calls, in fact each of them can send a call alert to a different device. The "reset" button is used to cancel the call made by the patient via the red button or perella, while the "A" and "B" buttons on the 3-channel device are reserved for operators in service, the cancellation of these buttons is carried out by keeping them pressed for at least 3 seconds. The message sent to the ALP100NW and ALP300W receivers can be customized, (for example the text "room 1 nurse call", "service call" etc ...). These keypads are equipped with a fixing and unlocking system with a special key.The call is made in differentiated mode with random delayed start at each call and the device verifies that the transmission channel is free, this to avoid call overlaps.

Features

• Check free transmission channel before signal transmission

• Acoustic and luminous signaling of low battery

• Call alarm not resolved • POCSAG transmission

• frequency deviation: +/- 2.5 KHz signal transmission

• Acoustic and luminous signaling of low battery

• Call alarm not resolved • POCSAG transmission

• frequency deviation: +/- 2.5 KHz

• Frequency stability +/- 10 PPM

• Major selectivity of 55 dB

• POCSAG transmission protocol

• Dimensions without flap: 70 x 70 mm

• Dimensions with flap: 92 x 92 mm The call is made in differentiated mode with random delayed start at each call and the device verifies that the transmission channel is free, this to avoid call overlaps

BLS1-HWPA call keypad with cancellation

Features

• Check free transmission channel before signal transmission

• Acoustic and luminous signaling of low battery

• Call alarm not resolved

• POCSAG transmission

• frequency deviation: +/- 2.5 KHz

• Acoustic and luminous signaling of low battery

• Automatic recall (3 times)

• Dimensions with flap: 92 x 92 mm

RJ11 connector that allows easy replacement of the patient call rod

BLS3-HWPA call keypad with nurse presence function

4-function call button with extension on nurse call red button dedicated to the patient's call reset button dedicated to patient call cancellation green keys for nurse presence indicated on the outside door lamp, gray key for leaving the room

 

Features

• Check free transmission channel before signal transmission

• Acoustic and luminous signaling of low battery

• Call alarm not resolved

• POCSAG transmission

• frequency deviation: +/- 2.5 KHz

• Acoustic and luminous signaling of low battery

• Automatic callback (3 times)

• Dimensions: 92 x 92 mm

ALP100-NW portable receiver

 

it is a portable pocket / belt receiver, has a large LCD display, can display

4-8 lines of text, and has a memory capacity of up to 3000 characters.

It has the function out of range alarm, battery warning download, unread message alarm, vibration and ringer function, zoom function for reading smoother than messages.

Equipped with adapter with belt / pocket clips.

Dimensions 76 x 53 x 18 mm

Weight: 68 gr with battery -

Battery type AAA 1,5V Rechargeable

Charging via USB socket

LD-02 2-line display

 

Wireless wall display 2 lines of 14 DIGIT Stand-by clock and date function Stores up to 30 calls

Dimensions: 650 x 165 x 31mm

Voltage: 12 Vdc

AD5001 21 "wall display 21 ”

 

wall display with indication of calls in progress and those on hold complete with bracket.

• Calls will change color based on the waiting times set green-yellow-red.

• The first call displayed in large at the top of the monitor and the other calls will be displayed in the lower part in sequence.

• Indication of current time and total number of calls on hold.

• Continuous or silent ringtone selection

SOF-MN1 (CALL MANAGEMENT SOFTWARE)

The system installed on a PC allows you to manage and monitor the calls received You can view reports on call response times divided by various sectors such as:

 

• call zone • single button

• call button • call operator

• day and time etc. Requires window XP system or higher Hardware connection via USB cable

 

REP-MN1 (REPORTING FORM)

 

Together with the SOF-MN1 software, it allows printing, exporting to excell and detailed display of the call reports. You can view reports on call response times divided by various sectors such as:

• call zone

• single button

• call button

• call operator

• day and time etc. Window XP system or higher required REP-MN1 REPORT module The system installed on a PC allows you to manage and monitor the calls received. You can view reports on call response times divided by various sectors such as:

• call zone

• single button

• call button

• call operator

• day and time etc. Requires window XP system or higher Hardware connection via USB cable SOF-MN1 Call management software

Alech srl

 

 Via Platone 22- 42048 - Reggio Emilia - Italy

P.I. IT02478720358